Latching Solenoid #01005
| |

Data Sheet
|
|
|
|
| |
Description:
The solenoid is energized to move to the latched position with a short voltage pulse. Once the voltage is removed, the permanent magnet maintains the solenoid in the latched position.
The solenoid is spring returned to the de-latched position by providing a short, reverse polarity voltage pulse, which cancels the permanent magnet field. Strokes and forces are flexible depending upon solenoid size.
Features:
- Compact design
- Low cost
- Can be optimized for specific load shifting capability
- Can be optimized to configure with customer power requirements
- Over 10,000 cycles on 4AA batteries
Possible Applications:
- Electric locks
- Electric oil meter control
- Computer case lock
- Computer docking station lock
- Business machines
- ATM machines
- Battery operated locks
- Medical supply cabinets
- Fuel controls
- Spool lock
- Business equipment
|
|
| |
| Typical Specifications: |
English (metric as applies) |
Stroke (can be designed to specification)
Net Latching Force
Supply voltage
Response time
Operating temperature range
Dynamic side load, (maximum)
Durability
Connector type |
0.06" ± .020" (1.5 mm)
<5.0 lbs (<22 N)
4.2 - 6.5 VDC
<15 msec
-40 to 140°F (-40 to 60°C)
10 lbs (44.5 N)
<10,000 cycles
Molex |
|
|
|